West Grove Fire Company
West Grove Fire Company


2025 Incidents
Fire EMS
Jan 92 339
Feb 91 301
Mar 111 328
Apr 54 272
May 0 331
Jun 0 0
Jul 0 0
Aug 0 0
Sep 0 0
Oct 0 0
Nov 0 0
Dec 0 0
Total 348 1571

2025 Incidents by Municipality
FIRE EMS
Franklin 33 112
London Britain 20 52
London Grove 83 319
London Derry 0 85
New London 34 146
Penn 75 492
West Grove 24 97
Mutual Aid 79 268
Total 348 1571

Past Incidents
Fire EMS
2024 863 3663
2023 728 3250
2022 673 3142
2021 611 2896
2020 580 2565
2019 651 2442
2018 657 2612
2017 665 2394
2016 708 2313
2015 560 2208
2014 619 2244
2013 577 2095
2012 577 1957
2011 534 2035

Web Counters
Website Visitors
Since
January 1, 2016
6,757,252
Visitors Today
Jun 30, 2025
2,711
WGFC Trains on Mechanical Ventilation
Email Print RSS Facebook Twitter RSS

September 15, 2020

Continuing a proven reputation for ongoing training, the West Grove Fire Company used its Monday drill night to familiarize crews with various methods of ventilation.

When attacking a fire, crews need to move smoke, heat and dangerous gasses out of the burning room (or any enclosed hazardous space) where they are working. A number of methods can be used for ventilation -- some involve mechanical means, others may be simple like opening windows and doors, or more intensive like opening up walls or cutting holes in roofs.

During this week's training session, the WGFC training reviewed mechanical methods of ventilation. These include several types of powered fans and the use of hose lines. In the case of fans, these devices -- powered by generator, gas engine or battery -- are used to create a positive pressure or negative pressure to vent a space.

The Fire Company has made an investment in battery-powered, positive-pressure fans. These are used to drive fresh air from outside a burning building into the interior, creating a positive pressure that drives smoke out of spaces that need to be cleared. These fans are portable and flexible for different operations. West Grove also has so-called "negative pressure" or exhaust fans -- designed to be put in a window, door or confined space and use the fan to pull smoke and heat from a space and eject it to the outside. These fans are typically powered by a generator on one of the fire trucks.

Lastly, firefighters can also use their attack hose lines to move smoke, heat and gasses out of a fire room, by flowing water out of a window or door. The flow of water, typically with a fog pattern, creates a vortex that pulls heat/gasses/smoke from the fire room to the exterior, and is a fast way for a hose line crew to vent a room in the immediate aftermath of knocking the fire down.

WGFC crews trained on each of these methods at the New London station, where the Company’s Fire Simulation Trailer was used for the class. The trailer creates safe, chemically-made smoke to allow firefighters to train in safe but realistic conditions.

Units: Rescue 22, Engine 22-1, Engine 22-2, Tanker 22
 
 

Add a Comment Add a Comment 0 Comment(s)


Website Designed and Hosted By: Content Proudly Maintained By: Contact Info:
Firehouse Solutions
www.FirehouseSolutions.com
West Grove Fire Company
PO Box 201
West Grove, PA, 19390
Emergency Dial 911
Non-Emergency: 610-869-9326
Station Fax: 610-869-4217
E-mail: info@wgfc.org
Copyright © 2025 Firehouse Solutions (A Service of Technology Reflections, Inc.)